Dell PowerEdge R715 User Manual

Page 46

Advertising
background image

46

About Your System

Read fault.

Requested sector

not found.

The operating system cannot

read from the hard drive,

optical drive, or USB device,

the system could not find a

particular sector on the disk,

or the requested sector is

defective.

Replace the optical medium,

USB medium or device.

Ensure that the SAS

backplane, USB, or SATA

cables are properly

connected. See

"Troubleshooting a USB

Device" on page 150,

"Troubleshooting an Optical

Drive" on page 161, or

"Troubleshooting a Hard

Drive" on page 162 for the

appropriate drive(s) installed

in your system.

SATA Port x

device not found.

There is no device connected

to the specified SATA port.

Information only.

SATA port x

device auto-

sensing error.

SATA port x

device

configuration

error.

SATA port 0

device failure.

The drive connected to the

specified SATA port is faulty.

Replace the faulty drive.

Requested sector

not found.

Seek error.

Seek operation

failed.

Faulty hard drive, USB

device, or USB medium.

Replace the USB medium or

device. Ensure that the USB

or SAS backplane cables are

properly connected. See

"Troubleshooting a USB

Device" on page 150 or

"Troubleshooting a Hard

Drive" on page 162 for the

appropriate drive(s) installed

in your system.

Shutdown

failure.

General system error.

See "Getting Help" on

page 183.

Message

Causes

Corrective Actions

book.book Page 46 Thursday, June 3, 2010 4:35 PM

Advertising