37

E2110 Multibit

Error on DIMM

##. Reseat

DIMM.

The memory module in slot

"##" has had a multi-bit

error (uncorrectable).

Reseat the memory

module in its socket.
If the problem persists,

see "Troubleshooting

System Memory" on

page 157.

E2111 SBE log

disabled on

DIMM ##.

Reseat DIMM.

The system BIOS disabled

memory single-bit error

(correctable) logging and

will not log any more SBEs

until the system is rebooted.

"##" represents the memory

module implicated by the

BIOS.

Reseat the memory

module in its socket.
If the problem persists,

see "Troubleshooting

System Memory" on

page 157.

E2112 Memory spared

on DIMM ##.

Power cycle

AC.

The system BIOS spared the

memory because it

determined that the

memory has too many

errors.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Troubleshooting

System Memory" on

page 157.

I1910 Intrusion

detected.

Check chassis

cover.

System cover removed.

Replace the chassis cover

or ensure the chassis cover

is properly installed. See

"Closing the System" on

page 79.

I1911 LCD Log Full.

Check SEL to

review all

Errors.

LCD overflow message. A

maximum of ten error

messages can display

sequentially on the LCD.

The eleventh message

instructs the user to check

the SEL for details on the

events.

Check the SEL for details

on the events.
Remove AC power to the

system for 10 seconds or

clear the SEL.

I1912 SEL full.

Review &

clear log.

The SEL is full of events

and is unable to log any

more.

Check the SEL for more

information and then

clear the SEL.

Code

Text

Causes

Corrective Actions