Dell PowerEdge R715 User Manual

Page 31

Advertising
background image

About Your System

31

E1715 Fatal I/O

Error. Review

& clear SEL.

The system BIOS

determined there has been a

fatal error in the system.

Check the SEL for more

information, and then

clear the SEL. Remove

AC power to the system

for 10 seconds, and restart

the system.
If the problem persists,

see "Getting Help" on

page 183.

E1716 Chipset IERR

Bus ## Dev ##

Function ##.

Review &

clear SEL.

The system BIOS reported a

chipset internal error that

resides in bus ##, device

##, function ##.

Check the SEL for more

information, and then

clear the SEL. Remove

AC power to the system

for 10 seconds, and restart

the system.
If the problem persists,

see "Getting Help" on

page 183.

E1717 CPU #

internal

error. Review

& clear SEL.

The system BIOS

determined that the

specified processor has had

an internal error.

Check the SEL for more

information, and then

clear the SEL. Remove

AC power to the system

for 10 seconds, and restart

the system.
If the problem persists,

see "Getting Help" on

page 183.

Code

Text

Causes

Corrective Actions

book.book Page 31 Thursday, June 3, 2010 4:35 PM