Alert! Node

Interleaving

disabled! Memory

configuration

does not support

Node

Interleaving.

The memory configuration

has changed (for example, a

memory module has failed)

so that node interleaving

cannot be supported. The

system will run but without

node interleaving.

Ensure that the memory

modules are installed in a

configuration that supports

node interleaving. Check

other system messages for

additional information for

possible causes. For memory

configuration information,

see "General Memory

Module Installation

Guidelines" on page 92. If

the problem persists, see

"Troubleshooting System

Memory" on page 157.

Alert! Power

required exceeds

PSU wattage.

Check PSU and

system

configuration.

Alert!

Continuing

system boot

accepts the risk

that system may

power down

without warning.

The system configuration of

processor(s), memory

modules, and expansion

cards may not be supported

by the power supplies.

If any system components

were just upgraded, return

the system to the previous

configuration. If the system

boots without this warning,

then the replaced

component(s) are not

supported with this power

supply. If Energy Smart

power supplies are installed,

replace them with the High

Output power supplies to use

the components. See "Power

Supplies" on page 87.

Alert! Redundant

memory disabled!

Memory

configuration

does not support

redundant

memory.

Redundant memory was

enabled in the system setup

program, but the current

configuration does not

support redundant memory.

A memory module may be

faulty.

Check the memory modules

for failure. See

"Troubleshooting System

Memory" on page 157. Reset

the memory setting, if

appropriate. See "Using the

System Setup Program and

UEFI Boot Manager" on

page 55.

Message

Causes

Corrective Actions