Dell PowerEdge R715 User Manual

Page 51

Advertising
background image

About Your System

51

HyperTransport

error caused a

system reset!

Please check the

system event log

for details!

A fatal system error occurred

and caused the system to

reboot.

Check the SEL for

information that is logged

during the error. See the

applicable troubleshooting

section in "Troubleshooting

Your System" on page 149,

for any faulty components

specified in the SEL.

Warning:

Following faulty

DIMMs are

ignored:

DIMM n1 n2

Total memory size

is reduced.

Faulty or improperly seated

memory module(s). Check

both DIMMs in the same

channel for a possible fault.

See "Troubleshooting Your

System" on page 149.

Warning:

Following faulty

DIMMs are

disabled:

DIMM n1 n2

Total memory size

is reduced.

Faulty or improperly seated

memory module(s). Check

both DIMMs in the same

channel for a possible fault.

See "Troubleshooting Your

System" on page 149.

Warning: The

installed memory

configuration is

not optimal. For

more information

on valid memory

configurations,

please see the

system

documentation on

the technical

support web site.

Invalid memory

configuration. The system

will run but with reduced

functionality.

Ensure that the memory

modules are installed in a

valid configuration. See

"General Memory Module

Installation Guidelines" on

page 92. If the problem

persists, see

"Troubleshooting System

Memory" on page 157.

NOTE:

For the full name of an abbreviation or acronym used in this table, see the

Glossary

at support.dell.com/manuals.

Message

Causes

Corrective Actions

book.book Page 51 Thursday, June 3, 2010 4:35 PM