Dell PowerEdge R715 User Manual

Page 49

Advertising
background image

About Your System

49

Unsupported CPU

combination.

Unsupported CPU

stepping

detected.

Processor(s) not supported

by the system.

Install a supported processor

or processor combination.

See "Processors" on page 123.

Unsupported DIMM

detected. The

following DIMM

has been

disabled: x

Invalid memory

configuration. The system

will run but with the

specified memory module

disabled.

Ensure that the memory

modules are installed in a

valid configuration. See

"General Memory Module

Installation Guidelines" on

page 92.

Unsupported

memory

configuration.

DIMM mismatch

across slots

detected:

x,x,...

Invalid memory

configuration. Memory

modules are mismatched in

the specified slots.

Ensure that the memory

modules are installed in a

valid configuration. See

"General Memory Module

Installation Guidelines" on

page 92.

Warning: A fatal

error has caused

system reset!

Please check the

system event log!

A fatal system error occurred

and caused the system to

reboot.

Check the SEL for

information that was logged

during the error. See the

applicable troubleshooting

section in "Troubleshooting

Your System" on page 149 for

any faulty components

specified in the SEL.

Warning: Front

Control Panel is

not installed.

The control panel is not

installed or has a faulty cable

connection.

Install the control panel, or

check the cable connections

between the control panel

board and the system board.

See "Control Panel

Assembly" on page 138.

Warning! No micro

code update

loaded for

processor n.

Micro code update failed.

Update the BIOS. See

"Getting Help" on page 183.

Message

Causes

Corrective Actions

book.book Page 49 Thursday, June 3, 2010 4:35 PM