Dell PowerEdge R715 User Manual

Page 38

Advertising
background image

38

About Your System

W1100 CPU VCORE

Regulator

temp

exceeding

range. Check

fans.

The regulator temperature

reached a point outside the

allowed range.

See "Troubleshooting

System Cooling

Problems" on page 155. If

the problem persists, see

"Getting Help" on

page 183.

W1102 Mem Voltage

Regulator

temp

exceeding

range. Check

fans

The regulator temperature

reached a point outside the

allowed range.

See "Troubleshooting

System Cooling

Problems" on page 155. If

the problem persists, see

"Getting Help" on

page 183.

W1228 RAID

Controller

battery

capacity <

24hr.

Warns predictively that the

RAID battery has less than

24 hours of charge left.

Allow RAID battery to

charge to greater than 24

hours of sustained charge.
If problem persists,

replace the RAID battery.

See "RAID Battery

(Optional)" on page 116.

W1630 Power supply

redundancy

degraded.

Check PSU

cables.

The power supply subsystem

is no longer fully redundant.

Reseat the power supplies.

See "Troubleshooting

Power Supplies" on

page 155.
If the problem persists,

see "Getting Help" on

page 183.

NOTE:

For the full name of an abbreviation or acronym used in this table, see the

Glossary

at support.dell.com/manuals.

Code

Text

Causes

Corrective Actions

book.book Page 38 Thursday, June 3, 2010 4:35 PM

Advertising