- Enable/disable the Abnormal Event check box, to set the condition of the event for system to

alarm.

System Reboot: when the DVR system reboot without abnormal condition, the system

will send out the alarm message.

Abnormal Reboot: when the DVR system reboot in irregular condition, the system will

send out the alarm message.

Recording is switched off: when the recording has been stopped, the system will send

out the alarm message.

Network is switched off: when the network connection of DVR system is lost, the

system will send out the alarm message.

Hard Disk failed: when the hard disk

doesn’t work normally, the system will send out

the alarm message.

S.M.A.R.T.:

select the risk level (High or Low) that base on the DVR system’s S.M.A.R.T.

mechanism to detect the hard disk’s status and the system will send out the alarm

message when the status has matched the selected risk level.

Temperature: set a temperature limited of system for system to alarm. When DVR

system temperature is over the temperature limited, the

system will send out the alarm. The system supports °C

and °F temperature mode.

Illegal Entry: any objects move between selected

regions which user has set up in Object Counting

section (see

Chapter 5.2.3

), the system will send out

the alarm. Select the entry (object moves from region 1

to 2 or from region 2 to 1) and click the Detail to select

the camera and the times for system alarm.