DMLERR_NOTPROCESSED
4330 Conversion application does not support DDE: A client’s attempt to establish a conversation
has failed. DMLERR_NO_CONV_ESTABLISHED
4331 A request for a synchronous poke transaction has timed out:
DMLERR_POKEACKTIMEOUT
4332 The DDE system failed calling its internal PostMessage function:
DMLERR_POSTMSG_FAILED
4333 Attempted reentrant DDE call: An application instance with a synchronous transaction already
in progress attempted to initiate another synchronous transaction, or the DdeEnableCallback function
was called from within a DDEML callback function. DMLERR_REENTRANCY
4334 The conversion application terminated during a DDE command: A serverside transaction
was attempted on a conversation terminated by the client, or the server terminated before completing a
transaction. DMLERR_SERVER_DIED
4335 The DDE system failed due to unspecified internal error:
DMLERR_SYS_ERROR
4336 DDE timeout attempting to terminate an advise transaction:
DMLERR_UNADVACKTIMEOUT
4337 DDE invalid transaction identifier: An invalid transaction identifier was passed to a DDEML
function. Once the application has returned from an XTYP_XACT_COMPLETE callback, the transaction
identifier for that callback function is no longer valid. DMLERR_UNFOUND_QUEUE_ID
4.1.2 1032–1140: Class 1 Driver
1071 Bad open ring 0 / kernel mode driver: There is another instance of the Class1 driver already
loaded, or the Windows account attempting to load the driver does not have Administrative permissions.
1087 No modem response: The modem did not respond to any commands. Check cabling or if this is
a PCI card modem, check that the card is properly seated.
Also try shutting the server down, leaving it off for 60 seconds, and powering it back on. Error type:
NON_RETRYABLE.
1088 Invalid response from modem: The modem sent a response not allowed by the Class 1
specification. Error type: NON_RETRYABLE.
1089 Not a Class 1 modem: The modem does not support the Class 1 command set. Error type:
NON_RETRYABLE.
1089 Send data was not supplied to the modem fast enough: Check serial port settings to
ensure the fax server can send data fast enough to the modem. Error type: RETRYABLE.
1095 Send collided with receive: An outbound port was allocated just as the port began to receive a
call. Error type: BUSY.
1106 Modem did not detect fax device on calling side: The modem returned something other
than CONNECT after answering the phone. This usually indicates the caller was not a fax machine.
Error type: NON_RETRYABLE.
1107 Modem did not detect carrier on calling side: The carrier wait timer expired after answering
the phone for receive. This usually indicates the caller was not a fax machine. The carrier_wait timer is
45 seconds by default.Error type: NON_RETRYABLE.
1108 Timed out waiting for a command: During phase B, the T1 timer expired while waiting for
commands from the sending fax machine. This timer is 35 seconds. Error type: NON_RETRYABLE.
1109 Timed out waiting for a command: The 3 second T4 timer or the 6 second T2 timer has
expired while waiting for a command from the sending faxmachine. Error type: NON_RETRYABLE.
1110 CLASS1 buffer full: The calling application has allowed more than 3 pages to be accumulated in