Som 9s – STIEBEL ELTRON SOM 9s User Manual

Page 15

Advertising
background image

© Stiebel 11091_SOM_9s.mon

us.ind

d

15 |

SOM 9s

R3

R1

S3

S2

S1

Temp. Sensor

Pt1000

L

R3

R2

R1

GND

S1

S2

S3

S4

S5

VBus

PWM

1

PWM

2

N

R4

V40

L'

VFS

RPS

out

in

The controller compares the temperature at sensor S1 to
the temperatures at sensors S2 and S3. If the measured
temperature differences are higher than the adjusted switch-
on temperature differences, the pump (R1) will be activated

and the corresponding tank zone will be loaded up to the
adjusted maximum temperature via the valve (R3). The prio-
rity logic effects prior loading of the upper zone of the tank.

Sensor/Ter-
minal

Designation

Description

S1

TCOL

Temperature collector

S2

TSTB

Temperature tank bottom

S3

TSTT

Temperature tank top

S4

Optional sensor for measurement
purposes or options

S5

VFS
RPS
V40

Relay

Description

R1

Solar pump

R2/R4

optional:
Thermal disinfection
Parallel relay
Heat dump

R3

3-port valve tank top/bottom

Adjustment channels

Channel

Sub channel 1

Sub channel 2 Factory

setting

Change to

Description

Page

ARR

1

4

System

78

LOAD1 >

Loading 1

DT1O

12 °R

Switch-on temperature difference 1

78

DT1F

8 °R

Switch-off temperature difference 1

78

DT1S

20 °R

Set temperature difference 1

78

RIS1

4 °R

Rise 1

78

S1MAX

140 °F

Tank maximum limitation 1

78

SMXS1

2

Sensor tank max 1

79

LOAD2 >

Loading 2

DT2O

12 °R

Switch-on temperature difference 2

78

DT2F

8 °R

Switch-off temperature difference 2

78

DT2S

20 °R

Set temperature difference 2

78

RIS2

4 °R

Rise 2

78

S2MAX

140 °F

Tank maximum limitation 2

78

System 4
Solar system with 1 tank and 3-port valve for vertical tank loading

Note: 3-port valve normally open - tank bottom

Advertising