Adjustment channels

Channel

Sub channel 1 Sub channel 2 Factory

setting

Change to Description

Page

ARR

1

14

System

78

LOAD1 >

Loading 1

DT1O

12 °R

Switch-on temperature difference 1

78

DT1F

8 °R

Switch-off temperature difference 1

78

DT1S

20 °R

Set temperature difference 1

78

RIS1

4 °R

Rise 1

78

S1MAX

140 °F

Tank maximum limitation 1

78

SMXS1

2

Sensor tank max 1

79

LOAD2 >

Loading 2

DT2O

12 °R

Switch-on temperature difference 2

78

DT2F

8 °R

Switch-off temperature difference 2

78

DT2S

20 °R

Set temperature difference 2

78

RIS2

4 °R

Rise 2

78

The controller compares the temperature at sensor S1 to
the temperatures at sensors S2 and S3. If the measured
temperature differences are higher than the adjusted switch-
on temperature differences, the pump (R1) will be activated
and the corresponding tank zone will be loaded up to the

adjusted maximum temperature via the valve (R3). The prio-
rity logic effects prior loading of the upper zone of the tank.
With another temperature differential function (S3-heat
source/S4-heat sink) heating circuit return preheating (hea-
ting circuit backup) is possible via another valve (R2).

System 14
Solar system with vertical tank loading and return preheating

R3

R2

R1

S4

S3

S2

S1

Temp. Sensor

Pt1000

L

R3

R2

R1

GND

S1

S2

S3

S4

S5

VBus

PWM

1

PWM

2

N

R4

V40

L'

VFS

RPS

out

in

Sensor/Ter-
minal

Designation

Description

S1

TCOL

Temperature collector

S2

TSTB

Temperature tank bottom

S3

TSTT/TSTR Temperature tank top/

Temp. tank return preheating

S4

TRET

Temperature return

S5

Optional sensor for measurement
purposes or options

VFS
RPS
V40

Relay

Description

R1

Solar pump

R2

Return preheating

R3

3-port valve tank top/bottom

R4

optional:
Thermal disinfection
Parallel relay
Heat dump

Note: 3-port valve normally open - tank bottom