Som 9s – STIEBEL ELTRON SOM 9s User Manual

Page 23

Advertising
background image

© Stiebel 11091_SOM_9s.mon

us.ind

d

23 |

SOM 9s

The controller calculates the temperature difference bet-
ween collector sensor S1 and tank sensor S2. If the diffe-
rence is larger than or identical to the adjusted switch-on
temperature difference, the pump (R1) will be switched on
and the tank will be loaded until the switch-off temperature

difference or the maximum tank temperature is reached.
With another temperature differential function (S4/S3),
backup heating of the tank can be carried out with a solid
fuel boiler (R3).

Sensor/Ter-
minal

Designation

Description

S1

TCOL

Temperature collector

S2

TSTB

Temperature tank bottom

S3

TSTT

Temperature tank top

S4

TSFB

Temperature solid fuel boiler

S5

Optional sensor for measurement
purposes or options

VFS
RPS
V40

Relay

Description

R1

Solar pump

R3

Loading pump solid fuel boiler

R2

optional:
Thermal disinfection
Booster pump
Parallel relay
Heat dump

R4

Adjustment channels

Channel

Sub channel 1

Sub channel 2 Factory

setting

Change to

Description

Page

ARR

1

8

System

78

LOAD >

Loading

DT O

12 °R

Switch-on temperature difference

78

DT F

8 °R

Switch-off temperature difference

78

DT S

20 °R

Set temperature difference

78

RIS

4 °R

Rise

78

S MAX

140 °F

Tank maximum limitation

78

SMAXS

2

Sensor tank max

79

COL >

Collector

CEM

270 °F

Collector emergency temperature

80

OCCO**

OFF

Option collector cooling

80

CMAX

230 °F

Maximum collector temperature

80

OCMI

OFF

Option collector minimum limitation

80

System 8
Solar system with 1 tank and backup heating with solid fuel boiler

R3

R1

S4

S3

S2

S1

Temp. Sensor

Pt1000

L

R3

R2

R1

GND

S1

S2

S3

S4

S5

VBus

PW

M

1

PW

M

2

N

R4

V4

0

L'

VFS

RPS

out

in

Advertising