Som 9s – STIEBEL ELTRON SOM 9s User Manual

Page 91

Advertising
background image

© Stiebel 11091_SOM_9s.mon

us.ind

d

91 |

SOM 9s

Energy metering with flowmeter V40

Î

2FTYPeFIMPMeDT MeD%Energy metering with
VFS sensor:

Î

FTYPeMeDT MeD%

OHQM / FIMP

Impulse rate
Adjustment range: 0.5 ... 99.0
in steps of 0.1
Factory setting: 1.0

note:
To deactivate the VFS or the RPS sensor, the
functions using these sensors have to be deac-
tivated first.

GFDS / OFLOW

Selection: ON / OFF
Factory setting: OFF

HQM sensors

OHQM / SFHQM

Flow sensor
Adjustment range: 1, 2, 3, 5
Factory setting: 1

If the flow rate detection type FMAX or V40 has been ad-
justed, the flow and the return sensor for energy metering
can be selected.

Î

In the channel SFHQM select the flow sensor.

Î

In the channel SRHQM select the return sensor.

For this function, free sensors at an appropriate position can
be selected. The pre-adjusted flow sensor is S1, the return
sensor is S4.

OHQM / SRHQM

Return sensor
Adjustment range: 2, 3, 4, 5
Factory setting: 4

In this menu point the Grundfos sensors can be registered.
If Grundfos sensors (VFS) are connected and registered,
flow rate monitoring OFLOW can be carried out during
solar loading. If no flow rate has been detected for 30 s, the
error message eFLOW is diplayed in the status menu (see
flow rate monioring option).

Grundfos sensors and flow rate monitoring

Antifreeze type:
0 : water

1 : propylene glycol

2 : ethylene glycol

3 : Tyfocor

®

LS / G-LS

OHQM / MED%

Antifreeze concentration in
vol.%
MED% is “hidden” when
MEDT 0 or 3 is used
Adjustment range: 20 ... 70 %
in steps of 1 %
Factory setting: 45 %

GFDS / VFS

Selection: OFF / 1-12 / 2-40
Factory setting: OFF

GFDS / RPS

Selection: OFF / 0-10
Factory setting: OFF

Advertising