| 62

SOM 9s

The controller compares the temperatures at the collector
sensors S1 and S5 to the tank temperatures at the sensors
S2 and S3. If one of the measured temperature differences is
higher than the adjusted switch-on temperature differences,
the corresponding pump (R1, R2) or both pumps will be
activated and the corresponding tank zone will be loaded

up to the adjusted maximum temperature via the valve (R3).
The priority logic effects prior loading of the upper zone
of the tank.
Domestic hot water backup heating (R4) can be carried out
with a thermostat function (S3).

Adjustment channels

Channel

Sub channel 1

Sub channel 2 Factory

setting

Change to

Description

Page

ARR

1

25

System

78

LOAD1 >

Loading 1

DT1O

12 °R

Switch-on temperature difference 1

78

DT1F

8 °R

Switch-off temperature difference 1

78

DT1S

20 °R

Set temperature difference 1

78

RIS1

4 °R

Rise 1

78

S1MAX

140 °F

Tank maximum limitation 1

78

SMXS1

2

Sensor tank max 1

79

LOAD2 >

Loading 2

DT2O

12 °R

Switch-on temperature difference 2

78

Sensor/Ter-
minal

Designation

Description

S1

TCOL1

Temperature collector 1

S2

TSTB

Temperature tank bottom

S3

TSTT

Temperature tank top

S4

Optional sensor for measurement
purposes or options

S5

TCOL2

Temperature collector 2

VFS

Optional sensor for measurement
purposes or options

RPS
V40

Relay

Description

R1

Solar pump collector 1

R2

Solar pump collector 2

R3

3-port valve tank top/bottom

R4

Backup heating/tank loading pump

System 25
Solar system with east-/west collectors, vertical tank loading and thermostatic backup heating

R4

R3

R2

R1

S5

S3

S2

S1

Temp. Sensor

Pt1000

L

R3

R2

R1

GND

S1

S2

S3

S4

S5

VBus

PW

M

1

PW

M

2

N

R4

V4

0

L'

VFS

RPS

out

in

Note: 3-port valve normally open - tank bottom