Som 9s, Osdc / form, Osdc / llog – STIEBEL ELTRON SOM 9s User Manual

Page 93: Osdc / remc, Osdc / logi, Lang, Osdc / osdc

Advertising
background image

© Stiebel 11091_SOM_9s.mon

us.ind

d

93 |

SOM 9s

Messages possible

Description

FSYS

File system error

CTYP

Card type is not supported

WRIT

Error during writing

NOCRD

No card in slot

LOGG

Logging is possible

WRITP

Card is write-protected

CFULL

Card full

RTIME

Remaining logging time in days

OSDC / FORM

Format card

When LLOg is activated, data logging will stop if the capa-
city limit is reached. The message CFULL will be displayed.
When LLOg (linear logging) is deactivated, the oldest data
logged onto the SD card will be overwritten as soon as the
capacity limit is reached.

OSDC / LLOG

Linear logging
Selection: ON / OFF
Factory setting: OFF

OSDC / REMC

Safely remove card
Selection: ON / OFF
Factory setting: OFF

OSDC / LOGI

Logging interval
Adjustment range: 1 ... 1200 s
Factory setting: 60 s

Language

In this adjustment channel, the menu language can be
chosen.
dE : German
En : English

LANG

Language
Selection: dE,En
Factory setting: En

SD card

If an SD card is used,

COM

is shown on the display. If the SD

card is full,

COM

is flashing.

Starting the logging

Î

Insert the SD card into the slot

Logging will start immediately.

Î

Adjust the desired logging interval

OSDC / OSDC

SD card
Selection: ON / OFF
Factory setting: OFF

Messages possible

Description

REMC

Safely remove card command

-REM

Card is being removed

FORM

Formatting SD card command

--FORM

Formatting in progress

LOGI

Logging interval in min

LLOG

Linear logging

Completing the logging process

Î

Select the menu item ReMC

Î

After -ReM is displayed remove the card from the slot

Formatting the SD card

Î

Select the menu item FORM

During the formatting process, --FORM will be displayed.
The content of the card will be deleted and the card will be
formatted with the FAT file system.

note:
Because of the increasing size of the data packets,
the remaining logging time does not decrease
linearly. The data packet size can increase, e. g.
with the increasing operating hours value.