System 7
Solar system with east-/west collectors
The controller compares the temperatures at the collector
sensors S1 and S5 to the tank temperature at sensor S2.
If one of the measured temperature differences is higher

than the adjusted switch-on temperature differences, the
corresponding pump (R1, R2) will be activated and the tank
will be loaded.

Sensor/Ter-
minal

Designation

Description

S1

TCOL1

Temperature collector 1

S2

TSTB

Temperature tank bottom

S3

Optional sensor for measurement
purposes or options

S4
S5

TCOL2

Temperature collector 2

VFS

Optional sensor for measurement
purposes or options

RPS
V40

Adjustment channels

Channel

Sub channel 1

Sub channel 2 Factory

setting

Change to

Description

Page

ARR

1

7

System

78

LOAD >

Loading

DT O

12 °R

Switch-on temperature difference

78

DT F

8 °R

Switch-off temperature difference

78

DT1S

20 °R

Set temperature difference

78

RIS

4 °R

Rise

78

S MAX

140 °F

Tank maximum limitation

78

SMAXS

2

Sensor tank max

79

COL 1 >

Collector 1

CEM1

270 °F

Collector emergency temperature 1

80

OCCO1**

OFF

Option collector cooling 1

80

CMAX1

230 °F

Maximum collector temperature 1

80

OCMI1

OFF

Option collector minimum limitation 1

80

CMIN1

50 °F

Minimum collector temperature 1

80

OTCO1

OFF

Option evacuated tube collector function 1 81

R2

R1

S5

S2

S1

Temp. Sensor

Pt1000

L

R3

R2

R1

GND

S1

S2

S3

S4

S5

VBus

PWM

1

PWM

2

N

R4

V40

L'

VFS

RPS

out

in