Adjustment channels

Channel

Sub channel 1

Sub channel 2 Factory

setting

Change to

Description

Page

RIS2

4 °R

Rise 2

78

S2MAX

140 °F

Tank maximum limitation 2

78

LST2

ON

Loading tank 2

79

COL 1 >

Collector 1

CEM1

270 °F

Collector emergency temperature 1

80

OCCO1**

OFF

Option collector cooling 1

80

CMAX1

230 °F

Maximum collector temperature 1

80

OCMI1

OFF

Option collector minimum limitation 1

80

CMIN1

50 °F

Minimum collector temperature 1

80

OTCO1

OFF

Option evacuated tube collector function 1

81

TCST1

07:00

Evacuated tube collector starting time 1

81

TCEN1

19:00

Evacuated tube collector ending time 1

81

TCRU1

30 s

Evacuated tube collector runtime 1

81

TCIN1

30 min

Evacuated tube collector standstill interval 1

81

OCFR

OFF

Option collector frost protection

82

CFR O

40 °F

Antifreeze temperature collector on

82

CFR F

42 °F

Antifreeze temperature collector off

82

COL 2 >

Collector 2

CEM2

270 °F

Collector emergency temperature 2

80

OCCO2**

OFF

Option collector cooling 2

80

CMAX2

230 °F

Maximum collector temperature 2

80

OCMI2

OFF

Option collector minimum limitation 2

80

CMIN2

50 °F

Minimum collector temperature 2

80

OTCO2

OFF

Option evacuated tube collector function 2

81

TCST2

07:00

Evacuated tube collector starting time 2

81

TCEN2

19:00

Evacuated tube collector ending time 2

81

TCRU2

30 s

Evacuated tube collector runtime 2

81

TCIN2

30 min

Evacuated tube collector standstill interval 2

81

LLOGI >

Loading logic

PRIO

Priority logic

82

PRIO

2

Priority logic

82

OSTS

OFF

Tank set option

83

TST1

120 °F

Set tank temperature tank 1

83

TST2

120 °F

Set tank temperature tank 2

83

DTSE

70 °R

Spread difference

83

tLB

2 min

Loading break time

82

tRUN

15 min

Circulation runtime

82

PSPEE

OFF

Pause speed option

83

PDELA

OFF

Pump delay option

83

OOVRU*

OFF

Overrun option

84

COOL >

Cooling functions

OSYC**

OFF

System cooling

85

OSTC

OFF

Tank cooling

85

OHDP**

OFF

Heat dump

85

DT3 >

Heat exchange

DT3O

12 °R

Switch-on difference

86

DT3F

8 °R

Switch-off difference

86

DT3S

20 °R

Set difference

86

RIS3

4 °R

Rise

86

MAX3O

140 °F

Switch-on temperature (maximum limitation) 86

MAX3F

136 °F

Switch-off temperature (maximum limitation) 86

MIN3O

40 °F

Switch-on temperature (minimum limitation)

86

MIN3F

50 °F

Switch-off temperature (minimum limitation)

86

S2DT3

4

Reference sensor heat sink

87

PUMP >

Pump speed

PUMP1

OnOF

Speed variant pump 1

79

PUMP2

OnOF

Speed variant pump 2

79

PUMP3

OnOF

Speed variant pump 3

79

MAN >

Manual mode

MAN1

Auto

Manual mode 1

88

MAN2

Auto

Manual mode 2

88

MAN3

Auto

Manual mode 3

88