Som 9s, 6functions and options – STIEBEL ELTRON SOM 9s User Manual

Page 75

Advertising
background image

© Stiebel 11091_SOM_9s.mon

us.ind

d

75 |

SOM 9s

Display of collector temperatures

TCOL(1, 2)

Collector temperature
Display range: -40 ... +500 °F

Display of tank temperatures

Displays the current tank temperature.
• TSTB : Tank temperature bottom
• TSTT : Tank temperature top
in 2-tank systems (only if available):
• TST1T : Temperature tank 1 top
• TST1B : Temperature tank 1 bottom
• TST2T : Temperature tank 2 top
• TST2B : Temperature tank 2 bottom

TST (1, 2)B, TST (1)T

Tank temperatures
Display range : -40 ... +500 °F

note:
The values and adjustment channels shown
depend on the selected system, the functions
and options and will only be displayed in the
expert level.

6

Functions and options

6.1

Status level

Displays the current collector temperature.
TCOL : Collector temperature (1-collector system)
TCOL1 : Collector temperature 1 (2-collector system)
TCOL2 : Collector temperature 2 (2-collector system)

Initialization

INIT

Initialization active

Filling time

FLLT

Filling time active

Stabilization

STAB

Stabilization

Display of drainback time periods

Indicates the time adjusted in tDTO, running backwards.

Indicates the time adjusted in tFLL, running backwards.

Indicates the time adjusted in tSTB, running backwards.

Blocking protection

BLPR1(2, 3)

Blocking protection active

Display of blocking protection time

Display of temperatures at S3, S4 and S5

Indicates the current temperature at the corresponding
additional sensor (without control function).
S3

: Temperature sensor 3

S4

: Temperature sensor 4

S5

: Temperature sensor 5

S3, S4, S5

Sensor temperatures
Display range : -40 ... +500 °F

note:
Only if temperature sensors are connected, will
S3, S4 and S5 be displayed.

note:
In systems with return preheating, S3/S5 is used
as the heat source sensor TSTR.

In order to protect the pumps against blocking after stand-
still, the controller is equipped with a blocking protection
function. This function switches on the relays every day at
12:00 a.m. for 10 s at 100%.