Display of pressure

BAR

Pressure
Display range: 0 ... 10 bar

Indicates the current system pressure.

note:
The pressure will only be indicated if an RPS
sensor is used.

Display of speed

n1 % , n2 % , n3 %

Current pump speed
Display range: 30 ... 100 %
standard pump;
20 ... 100 % HE pump

Indicates the current speed of the corresponding pump.

Operating hours counter

h R (1, 2, 3, 4)

Operating hours counter

The operating hours counter accumulates the solar ope-
rating hours of the relay (h R1 / h R2 / h R3 / h R4). Full
hours are displayed.
The accumulated operating hours can be set back to 0. As
soon as one operating hours channel is selected, the symbol

is displayed.

Î

In order to access the RESET-mode of the counter, press
the set button

5

.

The display symbol

will flash and the operating hours

will be set to 0.

Î

Confirm the reset with the set button

5

in order to

finish the reset.

In order to interrupt the RESET-process, do not press any
button for about 5 s. The display returns to the display mode.

Display of flow rate

L/h

Flow rate
Display range: 0 ... 9999 l/h

Indicates the measured current flow rate in the solar
system. The flow rate value is used for calculating the heat
quantity supplied (V40 / VFS).

TSFB, TRET, TSTR,
TFHQM, TRHQM,
TSFL(VFS), TSRE (RPS)

Other measured temperatures
Display range: -40 ... +500 °F

Indicates the current temperature at the corresponding
sensor. The display of these temperatures depends on the
system selected.
TSFB

: Temperature solid fuel boiler

TRET

: Temperature heating return

• TSTR

: Temperature tank return preahting

TFHQM : Temperature flow (HQM)
TRHQM : Temperature return (HQM)

Display of further temperatures