Tolerance Mode (LIMITS)

Take the following steps to select the appropriate tolerance mode.

Setting Range
The following modes are selectable.
• Reference value mode: Use this mode if there is a workpiece size change with the

deviations (tolerances) unchanged.

• Threshold mode:

Specify the upper and lower limits in absolute values.

1

Press the

ENT

key when the option

setting is displayed.

2

Press the

or

key and set the

tolerance mode.
The following displayed items can be
selected.

Reference value mode

Threshold mode

GO

GO

HI

GO

LO

3

Press the

ENT

key.

The input item is entered and the option setting display appears again.

PROG No.

PRINT

AREA

DISP

ESC

PROG

FUNC

ENT

H

ZE

FOCUS

2

1

A R E A

POSITION

G

L

Timing Mode

Take the following steps to set the synchronous (timing) input terminals corresponding to
OUT1 and OUT2 respectively.

Setting Range
Select the input terminals from the following ones.
• Asynchronous mode (ASYNC): The LS-7000 Series is in asynchronous control of

OUT1 and OUT2. Select the input terminals inde-
pendently for OUT1 and OUT2 respectively. Terminal
number 13 corresponds to OUT1 and connector I/O
number 38 corresponds to OUT2.

• Synchronous mode (SYNC):

The LS-7000 Series is in synchronous control of
OUT1 and OUT2. Terminal number 13 corresponds
to them. Connector I/O number 38 is disabled.

Refer to Section 6 I/O Terminals on page 6-1 for details.