Measurement of outer diameter and eccentricity – KEYENCE LS-7000 User Manual

Page 42

Advertising
background image

2-6

2

Chapter 2 Easy Setting Guide

Measurement of Outer Diameter and Eccentricity

In the following example, the outer diameter and eccentricity of the roller is measured while
the roller moves. The outer diameter is displayed as OUT1, and the eccentricity is dis-
played as OUT2.

Eccentricity

Outer diameter

Set Values

Set item

Calibration

Tolerance setting

Area setting

Output

setting

AREA

Operation

Averaging

Measuring mode

Offset

Set value

AREA 1

Head 1 DIA

Head 1 T-EDGE

Make settings if required.

A1: 1.0

A2: OFF

1

Average hold

A1: OFF

A2: 1.0

Select the value according to the rpm.

Peak-to-peak hold

No settings are required

No settings are required

Set the upper and lower limit values.

AREA 2

OUT 1

OUT 2

Reference

Area Settings (Page 4-7)
Calibration Settings (Page 4-20)
Output Settings (Page 4-28)
Tolerance Settings (Page 4-50)