Panel lock function – KEYENCE LS-7000 User Manual

Page 51

Advertising
background image

3-7

Chapter 3 Operation Control

3

Panel Lock Function

The panel lock function is used to lock the control panel so that no key input will be ena-
bled. As a result, there will be no risk of making setting changes with careless key input.

Panel Lock Types

The following types of panel locks are possible with the PAN-LOC settings as environment
settings. Refer to Panel Lock on page 5-13 for details.
• Set the panel lock type to ALL:

All keys will be locked.

• Set the panel lock type to PART: All keys excluding the DISP and AREA keys for the

display change function and

HI

,

GO

, and

LO

keys

for the tolerance setting function and

HOLD

key will be

locked. Select this type if you make tolerance changes
frequently without changing any other setting.

Panel Lock Display

The decimal in the PROG No. display will flash
while the panel is locked.

Tips

The panel lock status will not be
lost after the LS-7000 Series is
turned off or program number
changes are made.

PROG No.

NT

C

NT

Panel lock settings are made through the following functional components.
• Control panel
• RS-232C interface

Control Panel

Press the

and

keys on the

control panel together for 2 seconds.
To cancel the panel lock status, repeat the
above.

RS-232C Interface

Commands sent by external devices through the RS-232C interface make it possible to
set or cancel the panel lock function. Refer to Panel Lock ON/OFF on page 7-11.

PRO

PRINT

ESC

PROG

FUNC

ENT

Advertising