KEYENCE LS-7000 User Manual

Page 136

Advertising
background image

6-8

Chapter 6 I/O Terminals

6

The following table shows a list of program numbers and the status of the P1 terminal
through the P4 terminal.

Program number

P4

P3

P2

P1

0

OFF OFF OFF OFF

1

OFF OFF OFF ON

2

OFF OFF ON OFF

3

OFF OFF ON ON

4

OFF ON OFF OFF

5

OFF ON OFF ON

6

OFF ON ON OFF

7

OFF ON ON ON

8

ON OFF OFF OFF

9

ON OFF OFF ON

A

ON OFF ON OFF

B

ON

OFF

ON

ON

C

ON ON OFF OFF

D

ON ON OFF ON

E

ON ON ON OFF

F

ON ON ON ON

ON: Indicates the status of short-circuiting to the COM 1 terminal.
OFF: Indicates the open status of each terminal.
To change program numbers through I/O terminals, it is necessary to change the P-
SELECT setting as an environment setting to TERMINAL. Refer to Program Setting
Change on page 5-5 for environment settings in detail.

FUNCTION Output

Name

Description

Reference page

6-5, 6-6

FUNCTION output

One of the following functions (focus, area check,
and difference check) is selected and output.

FOCUS :

A-TEST :

DIFF

:

Turns ON or OFF in synchronization
with the results of focus monitoring.
(Normally open)
Turns ON when the area check
function is operating. (Normally open)
Turns ON once (for 26.6 ms) at the
time of difference detection. (Normally
open)