7-2

Chapter 7 RS-232C

7

Specifications

The LS-7000 Series has RS-232C communications functions. The following section pro-
vides information on the RS-232C communications specifications of the LS-7000 Series
and the outline of communications settings that vary with the connecting device.

Applicable Connector Specification

Modular 8-pin plug connector

Pin Arrangement

Pin number Signal name

Description

1

(Not used)

2

SD(TXD)

3

RD(RXD)

4

SG(GND)

GND

5

(Not used)

6

(Not used)

7

(Not used)

8

(Not used)

Receives (inputs into itself)

data from external devices.

Transmits (outputs) data

to external devices.

8

7

6

5

4

3

2

1

❈ All unused terminals must be open. Do not connect any wires to them, otherwise the

LS-7000 Series may malfunction.

❈ The SG terminal is internally connected (common) with the 0-V power supply termi-

nal (terminal block 2) through a choke coil.

Communications Specifications

EIA RS-232C Compliance (Modem Definitions)

D-MODE

NORMAL

PRINTER 1/2

PLC (KV mode)

Communications method

Full duplex

Synchronous method

Start-stop synchronization

Transmission code

ASCII

Data length

7/8bit

8bit

Stop bit length

1/2bit

1bit

Parity None/Even/Odd

Even

Baud rate

1200/2400/4800/9600/

9600bps

19200/38400/57600/115200bps

Delimiter

CR + LF

CR

STX + ETX

Flow control

None

Refer to RS-232C on page 5-7 for communications specification settings.