9.1.3 Specifications

Input/Output

Output

NPN open-collector output

Max. applicable voltage: 40 V

Max. sink current: 100 mA

Input

Non-voltage contact (relay) input or open-collector input.

Use the (17), (18) or (25) ground terminal.

These ground terminals are connected internally.

Analog Voltage Output

Output voltage: ±10 V

Impedance: 100

50 V

NPN
output

GND

12 V

1 K

470

IN

GND

IN

GND

or

0 V

47 Ω

47 Ω

OUTPUT