background image

Chapter 6 Normal Mode

35

6

4

4

4

4

4 Limit Setup

7-level-tolerance-limits can be set separately for four outputs. (

➮ See p.41 for

setting output.)

Setting Procedure
1. Select the LIMIT SETUP screen.

Press the [LIMIT SETUP] button. The screen shown below is displayed.

2. Set tolerance limits.

Press the button corresponding to the output for which you wish to set tolerance
limits.

Select a desired tolerance limit using the [

▲]/[ ] arrow keys.

Enter a value using the numeric keys, and press [ENTER].

Press [ESCAPE] to complete the entry.
Press [CANCEL] to cancel the entry. The value returns to the previous value.

Note 1: When a measured value exceeds the tolerance range, the measured value
is displayed in reverse. The differentiation result corresponding to the tolerance
limits is output from the display unit and the control I/O (option) board.

Note 2: Tolerance limits must conform to the following condition:
HI3 > HI2 > HI1 > LO3 > LO2 > LO1
Otherwise, the tolerance value cannot be entered. (The “ERR” message appears
on the display and the entered value cannot be accepted.)

Note 3: The maximum and minimum tolerance limit values are as follows:
Max.: 999.9999 (9.99999)
Min.: -99.9999 (-0.99999)
* Values in ( ) are the maximum and minimum values displayed in inches.

OUT1

• • •

OUT4

LIMIT

SETUP

LASER ON

SELECT OUTPUT

NOR

MAL

P. 1

DISPLAY

DATA

LIMIT

SETUP

PROGRAM

CALIB

OPTIONS

OUT1

OUT2

OUT3

OUT4

Select Output No. to set the limits.

LIMIT SETUP

OUT1

LASER ON

NOR

MAL

P. 1

8

7

5

6

4

2

3

1

.

-

0

9

ENTER

CANCEL

ESCAPE

HI3

30.0000

HI2

25.0000

HI3

20.0000

LO1

15.0000

LO2

10.0000

LO3

5.0000