2 trigger input signal type – KEYENCE N-400 User Manual

Page 101

Advertising
background image

93

Chapter 5 Multi-Head Mode Control Procedure

5

5.2.2 Trigger input signal type

When the trigger input is connected to the N-400 in multi-head mode, the trigger
signal is sent to all connected BL series to start the reading operation.

The trigger input signal type can be set for the N-400 as well as for the BL series.

“Level” trigger signal

While the trigger input is ON, the BL series reads bar code data.

“One-shot” trigger signal

After the rising edge of the trigger input is detected, the BL series reads bar code
data for the preset trigger time.

Reading

Trigger input

Communication
output

(When the BL series
successfully read bar code data)

(When the BL series failed to
read bar code data)

* Read error

Reading

Trigger input

Preset trigger time

Preset trigger time

Communication
output

(When the BL series
successfully read bar code data)

(When the BL series failed to
read bar code data)

* Read error

Advertising