H setup parameter list, Appendix h setup parameter list – KEYENCE N-400 User Manual

Page 145

Advertising
background image

137

Appendices

Appendices

Appendix H

Setup Parameter List

HOST MODE

TRIGGER SETUP (Effective in multi-head mode only)

PROTOCOL SETUP

Mode

Multi-drop link mode

Multi-head mode

Interference suppression

Disable

Enable

Trigger ON time for

( )

interference suppression

* 10 ms to 2550 ms

Reading mode

Single label

Multi label 1

Multi label 2

Data-send timing

After reading

At trigger OFF

Read error code

( )

* Up to eight characters

Trigger input signal type

Level

One-shot

One-shot input time

( )

* 100 ms to 25.5 s

Input time

2 ms

10 ms

State

Normally-open

Normally-closed

Trigger ON command

( )

* Up to eight characters

Trigger OFF command

( )

* Up to eight characters

PLC link

Disable Handshaking

No handshaking

PASS/RTRY

ACK/NAK

Header

None

STX

ESC

Custom ( ) * Up to five characters

Delimiter

CR

CR + LF

ETX

Custom ( ) * Up to five characters

Add ID

Do not add

Add

Checksum

Do not add

Add

Enable

PLC model name

SYSMAC-C

MELSEC-A

KV

PLC trigger area

Disable

Enable

DM head address

( ) 00

* 0000 to 9900

PLC station/

( )

* 000 to 255

unit number

File register

Disable

Enable

File register

( )

* 000 to 255

block number

Advertising