100

5

The following table shows the actual minimum scan time for each baud rate setting.

• Scan OFF time (M)

When the interference suppression function is used, a time lag occurs between the
scan of one BL series and the next. During this period, the BL series cannot read
bar code data.

• Scan cycle time (N)

The cycle time between the scan of one BL series and the next BL series is in-
creased when the number of connected BL series is increased or when the trigger
ON time is prolonged.

To reduce the scan cycle time (to scan bar codes on a high-speed line), reduce the
number of connected BL series or shorten the trigger ON time.

The scan cycle time can be calculated from the following formula:

N = (L + M) n * n = Number of connected BL series

Note: When the interference suppression function is used, the reading operation is
not applicable for a high-speed line because the scan OFF time of each BL series
is prolonged.

Baud rate (RS-485)

Actual minimum scan time (L)

9600 bps

141 ms

38400 bps

58 ms

Baud rate (for RS-485)

Scan OFF time (M)

9600 bps

36.5 ms

38400 bps

14.8 ms