Chapter 4 Multi-Drop Link Mode Control Procedure

4

Description of setup commands

Saving settings/Initializing settings/Quitting SETUP mode

HOST MODE

To set a read error code, use the following command format.

Example: To set the read error code to “BR”

WP554252

* B = 42h, R = 52h

Function

Command

Response

Description

Error code

Saving settings

SAVE

OK

See p. 74.

00, 02,

in the EEPROM

05, 14

Initializing

DFLT

OK

Resets the current settings

00, 02,

settings

to the default values and

05, 14,

saves them in the EEPROM.

15

Quitting

SEND

OK

See p. 74.

00, 02,

SETUP mode

05, 14

Tips

B R

Mode

Function

Command

Response Description

Change

WP00n

OK

n = 0: Multi-drop link
n = 1: Multi-head scan
mode

Confirm

RP00

00n

Interference
suppression
Trigger

Change

WP06n

OK

n = 0: Disable
n = 1: Enable

RP06

Confirm

06n

ON time in
interference
suppression
mode

Change

WP47nnn

OK

nnn = 001 to 255
(Units: 10 ms)

Confirm

RP47

47nnn

Read mode

Change

WP12n

OK

n = 0: Single
n = 1: Multi-label 1
n = 2: Multi-label 2

Confirm

RP12

12n

Data trans-
mission timing
(Effective in
signal label
mode only)

Change

WP13n

OK

n = 0: After read
n = 1: At trigger

Confirm

RP13

13n

Read error
code

Change

WP55hhh.. OK

hhh... = Read error code
(up to eight characters)
* To set a read error code,
use HEX (hexadecimal)
codes.
* hhh... = FF: Read error
code is not set.

Confirm

RP55

55hhh..

Error code

00, 02,
05, 07,
14

00, 02,
05, 07,
09, 14

00, 02,
05, 08,
14

00, 02,
05, 07,
14

00, 02,
05, 10,
12, 14