Indications on the N-400

The N-400 displays the following codes:

Status indication

These codes indicate that the N-400 is in a special condition.

S0 (

50

50

50

50

50

):

When you press and hold the test switch for five seconds, this code is displayed.
When the N-400 displays this code, the communication parameters are set as
follows: (

See p. 48.)

This code is used to send settings to the N-400 on the N-400 setup software.

Baud rate: 9600 bps
Data length: 7 bits
Parity: Even
Stop bit length: 1 bit
Using PLC link: Disable

S1(

51

51

51

51

51

):

The code indicates that the N-400 is in SETUP mode. This code is displayed after
the SSET command is sent, or while settings are sent to the N-400 or received
from the N-400 on the setup software.

Error indication

The following codes indicate that the N-400 is in an abnormal condition.

“99”:

99

99

99

99

99

That the N-400 is defective. If this error cannot be removed even when the test
switch is pressed, contact KEYENCE.

“98”:

98

98

98

98

98

Indicates an EEPROM memory error. All the settings will be initialized. Press the
test switch to reset this error.

“97”:

97

97

97

97

97

Indicates a data overflow in the N-400’s buffer. Press the test switch to reset this
error.

“96”, ”95”:

96 95

96 95

96 95

96 95

96 95

Displayed when communication is abnormal in PLC link mode. (Indicates a PLC
link error.) Press the test switch to reset this error.