Chapter 3 N-400 Setup Procedure

41

3

S018

PROTOCOL (when "Use PLC" is enabled)

To enable the "Use PLC", set each item as follows:

1. Set “Connected PLC”, “DM head address” and “Station No.”.

To set “DM head address”, enter a value (0000 to 9900) using the keyboard.

2. To send a trigger signal to the BL series when the PLC link is enabled, set

“PLC trigger area”.

3. To use “File Register”, set “File Register” to “Enable”. When “File Register” is

enabled, the following screen appears. The “File Register” can be used with
the Mitsubishi MELSEC-A series only.

Enter the block number (000 to 255) of the file register using the keyboard.

PLC link: p. 100

PLC trigger area: p. 106

DM head address: p. 106

File register: p. 101

The setting of the station
number is not displayed
when “KV Series” is selected.

The setting of the file register
is displayed only when
“MELSEC-A” is selected.