Chapter 2 Installation Procedure

21

2

2.4

Connecting BL-U1 and Wiring

To use the BL-U1 AC power supply, connect it as described below.

2.4.1 Connecting power supply

Plug the BL-U1 power cable into an outlet.

Use a power supply of 100 to 240 VAC

±

10% (50/60 Hz).

2.4.2 Connecting BL series

Connect the BL series to the READER port of the BL-U1.

BL-U1 READER port pin assignment

FG line

CAUTION

1 2 3 4

6 7 8 9

5

Pin No.

Symbol

Function

Signal direction

1

TIM

Trigger input

Output

2

RD (RXD)

Receives RS-232C data.

Output

3

SD (TXD)

Sends RS-232C data.

Input

4

OK

OK

Input

5

GND (SG)

Ground (Common ground for respective

signal)

6

NG

NG

Input

7

RS (RTS)

Ready to send RS-232C data.

Input

8

CS (CTS)

Request to send RS-232Cdata.

Output

(Control method can be selected with the DIP
switches. See p. 22.)

9

+5 V

+5 V power supply (1.5 A)

Output

D-sub 9-pin (male)
DCE specification (defined as terminal)
#4-40 screw (female)