2 connecting rs-232c, Caution, Connecting trigger input – KEYENCE N-400 User Manual

Page 21: Pin assignment, Rs-232c cable connections

Advertising
background image

Chapter 2 Installation Procedure

13

2

Connecting trigger input

To use multi-head scan mode, connect the trigger input to the N-400 only, instead
of to each BL series unit.

2.2.2 Connecting RS-232C

Pin assignment

Pin No. 25 is used for a 5 V power supply output. Do not connect this termi-
nal to the ground terminal or any other terminal when it is unused. Doing this
may damage the N-400 or the external device connected to this terminal.

RS-232C cable connections

Connecting personal computer

• Connecting the computer with 25-pin

• Connecting IBM PC

A commercially-available straight cable (D-sub 25 pin - 25 pin, or D-sub 25 pin - 9
pin) can be used.

CAUTION

2

Computer

SD

RD

RS

CS

DR

SG

ER

3

4

5

6

2

1

1

N-400

SD

FG

FG

RD

SG

RS

CS

DR

ER

3

4

5

6

7

20

7

20

D-sub 25-pin (male)
M2.6 screw

D-sub 25-pin (male)
M2.6 screw

2

PC

SD

CD

RD

RS

CS

DR

SG

ER

3

4

5

6

2

1

N-400

SD

FG

RD

SG

RS

CS

DR

ER

3

4

5

6

7

8

7

8

20

1

D-sub 25-pin (male)
M2.6 screw

Connector case

D-sub 9-pin (female)
#4-40 screw

Tips

TIM

SG

COM

15 to 26 VDC

+

+

Contact
or solid state

TIM

COM

Internal circuit

+

+

13

1

25

14

Pin No.

Symbol

Function

Signal direction

1

FG

Frame ground

2

SD (TXD)

Sends data.

Input

3

RD (RXD)

Receives data.

Output

4

RS (RTS)

Ready to send data.

Input

5

CS (CTS)

Request to send data.

Output

6

DR (DSR)

Connected to pin No. 20 inside.

Output

7

SG

Signal ground

20

ER (DTR)

Connected to pin No. 6 inside.

Input

25

+5 V

5 V power supply output (100 mA)

Output

* The OP-98769 cable (1.5 m: manu

factured by KEYENCE) and the
OP25057 conversion connector can
be used.

* The OP-98769 cable (1.5 m: manufactured

by KEYENCE) can be used.

D-sub 25-pin (male)
DCE specification (defined as terminal)
M2.6 screw

Advertising