Chapter 4 Multi-Drop Link Mode Control Procedure

78

4

TRIGGER INPUT SETUP (Effective in multi-head scan mode only)

To set the characters of the trigger ON/OFF commands, use the following com-
mand format:

Example: To change the trigger ON command to “[CR]” or “[STX]S[ETX]”.

WP5653

* S = 53h

S

Tips

Trigger
input signal
type

Function

Command

Response Description

Change

WP05n

OK

n = 0: Level

n = 1: One-shot

Confirm

RP05

05n

One-shot
input time

Change

WP42nnn

OK

nnn = 001 to 255

(Units: 100 ms)

RP42

Confirm

42nnn

Trigger
input
time

Change

WP04n

OK

n = 0: 2 ms

n = 1: 10 ms

Confirm

RP04

04n

State of
trigger input

Change

WP03n

OK

n = 0: Normally open

n = 1: Normally closed

Confirm

RP03

03n

Characters of
trigger ON
command

Change

WP56hhh...

OK

hhh... =

Trigger ON command
(up to eight characters)

* To set this command,
use HEX (hexadecimal)
codes.

Confirm

RP56

56hhh...

Characters of
trigger OFF
command

Change

WP57hhh.. OK

hhh... = Trigger OFF
command (up to eight
characters)
* To set this command,
use HEX (hexadecimal)
codes.

Confirm

57hhh..

Error code

00, 02,
05, 07,
14

00, 02,
05, 07,
09, 14

00, 02,
05, 07,
14

00, 02,
05, 06,
11, 14

00, 02,
05, 06,
11, 14

Advertising