69

Chapter 4 Multi-Drop Link Mode Control Procedure

4

4.4

N-400 Direct Control Commands

You can perform the following controls by sending a command to the N-400.
1) Assigning an ID number to the BL series for which auto polling is performed.

2) Setting auto polling mode to ON/OFF

3) Checking if the BL series is properly connected

4) Reading control command in multi-head scan mode

5) Resetting the N-400

The above control 1) can be set with the N-400 setup software. (

See p. 42.) The

above control 3) can be performed using the connection test switch provided on the
N-400. (

See p. 51.)

4.4.1 Communication procedure

Sequence and format for communication

1. Send a direct control command to the N-400 from the host computer.

2. After the N-400 receives the command, the N-400 sends back a response (e.g.

“OK” or “NG”) to the host computer.

Note: If an incorrect command is sent, the N-400 sends back no response.

The ID number is not specified in the command/response format.

The N-400 returns the response with the same header and delimieter as it
receives.

When the command format is [Command][CR], the response format is
[Response][CR]. When the command format is [STX][Command][ETX], the
response format is [STX][Response][ETX].

*

[LF] can be added to the end of the command. However, [LF] is not added to
the response.

*

When [ESC] is added to the head of the command, the N-400’s receiving buffer
is cleared. However, [ESC] is not added to the response.

(For a description of the commands, see the following pages.)

N-400

POLE00 CR

OK

CR

• • •

Auto

polling

ON

Command

Response

Command CR

Response CR

STX Command ETX

STX Response ETX

Advertising