3 connecting n-48 and wiring, 1 connecting the bl series, 2 terminals of i/o terminal block and connections – KEYENCE N-400 User Manual

Page 24

Advertising
background image

Chapter 2 Installation Procedure

16

2

2.3

Connecting N-48 and Wiring

2.3.1 Connecting the BL series

Connect the BL series to the READER port of the N-48.

Pin assignment

2.3.2 Terminals of I/O terminal block and connections

POWER

SD

RD

READER

N-48

BL series

1

2

3

4

5

6

7

8

9

Pin No.

Symbol

Function

Signal direction

1

TIM

Trigger input

Output

2

RD (RXD)

Receives data.

Output

3

SD (TXD)

Sends data.

Input

4

OK

OK

Input

5

GND (SG)

Ground (Common ground for respective signal)

6

NG

NG

Input

7

RS (RTS)

Ready to send data.

Input

8

CS (CTS)

Request to send data.

Output

9

+5 V

5 V power supply output (600mA)

Output

TIM COM OK NG COM

Symbol

Description

Signal direction

TIM

Trigger input

Input

COM

Common terminal for trigger input

Input

OK

OK output

Output

NG

NG output

Output

COM

Common terminal for output

Output

D-sub 9-pin (male)
DCE specification (defined as terminal)
#4-40 screw

* Viewed from the left of the unit

Advertising