Technical data, 5 ultracom, 35 store – Glow-worm Ultracom2 35 Store User Manual

Page 10

Advertising
background image

0020112185_PROTO_13 - 01/11 - Glow-worm

- 8 -

TECHNICAL DATA

5 Ultracom

2

35 Store

Boiler, type C13, C33, C43

Description

Unit

35 Store

Gas category

ll

2H3P

SEDBUK 2005 rating

%

NA

SEDBUK 2009 rating

%

NA

Heating

G20

Maximum heating input power

kW

30.6

Minimum heating output power

at 80/60°C (P min.)

kW

8.5

Maximum heating output power

at 80/60°C (P max.)

kW

30

Minimum heating output power

at 50/30°C (P min.)

kW

9.3

Maximum heating output power

at 50/30°C (P max.)

kW

32.5

PCI Efficiency max heating power

at 80/60°C

%

97.9

PCI Efficiency max heating power

at 50/30°C

%

106.3

Efficiency at part load (30%) on PCI

at 40°C/30°C

%

108.6

Efficiency level according to the European

Directive 92/42

-

Condensing

Minimum calorific rate (Q min.)

kW

8.7

Maximum calorific rate (Q max.)

kW

30.6

Minimum heating flow rate

l/h

400

Minimum heating temperature

°C

10

Maximum heating temperature

°C

80

Content of heating expansion vessel

l

12

gallons

2.64

Heating expansion vessel preset pressure

bar

0.75

psi

10.9

Max. capacity of the installation at 75°C

l

220

Heating safety valve preset pressure (PMS)

bar

3

MPa

0.3

Domestic Hot Water

G20

Minimum DHW output power (P min.)

kW

8.7

Maximum DHW output power (P max.)

kW

35.7

Min. calorific rate (Q min)

kW

8.7

Maximum calorific rate (Q max.)

kW

35.7

Minimum DHW temperature

°C

45

Maximum DHW temperature

°C

65

Specific flow rate (∆T of 35 K)

l/min

19.7

Specific flow rate according to EN 625

l/min

NA

Level of sanitary confort

EN 13203

-

***

Flow rate operating threshold

l/min

0.1

High capacity tank

l

42

Water flow limitor

l/min

16

Safety valve, maximum working pressure

(PMW)

bar

10

psi

145

Minimum inlet water pressure

bar

0.3

psi

4.3

Maximum inlet water pressure (*)

bar

10

psi

145

Description

Unit

35 Store

Maximum temperature hot water safety

valve

°C

90

Maximum pressure hot water safety valve

bar

10

psi

145

(*) For a supply pressure above 3 bar, it is recommended that you install

a pressure reducer.

Description

Unit

35 Store

Combustion

G20

Fresh air flow rate (1013 mbar -0°C)

m

3

/h

45.7

Flue gas

flow rate at Pmin.

g/s

4

Flue gas

flow rate at Pmax.

g/s

13.8

Flue gas

flow rate in hot water mode

g/s

16

Flue gas

temperature at Pmin. 80°C/60°C

°C

72.4

Flue gas

temperature at Pmin. 50°C/30°C

°C

47.4

Flue gas

temperature at Pmax. 80°C/60°C

°C

77.2

Flue gas

temperature at Pmax. 50°C/30°C

°C

55.8

Flue gas

temperature in hot water mode

(with hot water temperature of 50°C)

°C

81

Value of combustion products (measured at nominal calorific rate and

with G20 reference gas, in heating):

CO

ppm

NA

mg/

kWh

8

CO

2

%

9.2

Weighted Nox

ppm

22.6

mg/

kWh

39.8

Appliance NOx class

5

Electrical
Electrical supply

V/Hz

230/50

Standby mode electrical power

W

6

Operational mode electrical power (Max)

W

178

Intensity

A

0.75

Internal fuse rating on main PCB

A

2

Index of electrical protection

(EN 60529)

IPX4D

Electrical classification

I

Description

Unit

35 Store

Gas connection Ø O.D.

mm

15 (copper)

Heating flow and return connection Ø O.D.

mm

22 (copper)

Domestic Hot Water connection Ø O.D.

mm

22

(copper)

Safety valve discharge connection Ø O.D.

mm

22

(copper)

TECHNICAL DATA

Advertising