11.2 Main board

1

2

3

30 mm max.

Key

1 Connector

2 Electrical wires

3 Insulation

When you connect the electrical wires to a connector on the

electronic board:

• Keep a distance of a maximum of 30 mm between connector

(1) and the start of the insulation (3).

• If using single core wires are used(2) ensure that the are

wrapped together in an insulating sheath.

• Fix the cables in the cable-clamp on the eBox.

11.3 Electrical wiring

Connection of the whole electrical system and any heating system

controls to the electrical supply must be through a common

isolator.

Isolation should preferably be by a double pole switched fused

spur box having a minimum contact separation of 3mm on

each pole. The fused spur box should be readily accessible and

preferably adjacent to the boiler. It should be identified as to its

use.

A fused three pin plug and shuttered socket outlet may be used

instead of a fused spur box provided that it is not used in a room

containing a fixed bath or shower.

1

Key

1 Power supply cable

• Connect the appliance's power cable to the 230 V single-phase

network + earth.

• Connect the appliance in accordance with the live and neutral

connections.