Installation, 10 remove the front panel, 11 electrical connections – Glow-worm Ultracom2 35 Store User Manual

Page 26

Advertising
background image

0020112185_PROTO_13 - 01/11 - Glow-worm

- 24 -

10 Remove the front panel

A

B

A

2

1

Key

1 front panel retaining screw

2 front panel

• Undo the two screws (1) on the underside of the front panel

and remove the front panel (2).

11 Electrical connections

e

Incorrect installation can cause electric shock or

appliance damage. The electrical connection of the

appliance must be made only by a qualified engineer.

The appliance must be connected directly to an accessible, fixed,

switched, electrical outlet.

The external wiring must be earthed, with correct polarity and in

accordance with current standards.

The manufacturer declines any responsibility for damages to

persons or others caused by the incorrect installation of the

appliance earthing. This includes failure to comply with current

standards.

Electrical components have been tested to meet the equivalent

requirements of the BEAB.

• Do not use cable greater than 10 mm in diameter for the

electrical connections.

All system components must be of an approved type.

• Do not interrupt the mains supply with a time switch or

programmer.

The boiler is suitable for installation in bathroom zones 2 and 3.

11.1 Access to main board

i

It is necessary to remove the appliance front cover.

230

V

2

1

Key

1 User interface

2 fastening screw

• Pivot the user interface to access the electrical panel.

230

V

2

1

Key

1 230 V access cover

2 24 V access cover

• Tilt the user interface panel to access the 24V and 230V

connections.

INSTALLATION