Installation, Ab c – Glow-worm Ultracom2 35 Store User Manual

Page 14

Advertising
background image

0020112185_PROTO_13 - 01/11 - Glow-worm

- 12 -

Prevention of scalding - Thermostatic mixing valve

2

1

A

B

C

Key

1 Thermostatic mixing valve

2 Standard flue length horizontal

A Hot water

b Cold water

C Mixed water

A thermostatic mixing valve is used in

the

domestic hot water

circuit.

It’s function is to maintain the temperature of the mixed water,

supplied to the user, constant at the set value when there

are variations in the supply pressure and temperature of the

incoming hot and cold water or in the flow rate.

The hot water supply temperature to a bath should be limited to

a maximum of 48°C. The thermostatic mixing valve should not be

easily altered by users.

The thermostatic mixing valve conforming to WRAS,

BS EN

1111

and

BS EN

1287, compliant to Part G of the bluiding regulations.

7.2.2

Heating circuit design

6

4

5

3

2

1

8

7

9

10

Key

1 Drain point

2 External bypass (if required)

3 Domestic cold water supply in

4 Domestic hot water out

5 Pressure reducing valve (if required)

6 boiler

7 filling loop in accessory box

8 Additional expansion vessel (if required)

9 Heating return circuit

10 Heating flow circuit

General

This boiler is designed for use as part of a sealed water central

heating system with fully pumped circulation. The pump,

expansion vessel and associated safety devices are all fitted

within the boiler.

Safety valve

The safety valve is an integral part of the boiler and it cannot

be adjusted. The pipe from the safety discharge valve must

discharge safely in accordance with standards.

Expansion vessel

The boiler has an integral expansion vessel with a capacity of 12

litres (2.64 gallons), with a charge pressure of 0.75bar.

i

The heating system volume should be calculated to

ensure that the expansion vessel is suitable, it may be

necessary to add an additional vessel.

- In GB, Guidance on vessel sizing is also given in the current

issue of BS5449 and BS7074 Part 1.

- In IE, current edition of I.S.813 “Domestic Gas Installations”

.

Bypass

The boiler is fitted with an automatic bypass which can be

adjusted to suit your system requirements.

• Ensure that under no circumstances does the flow rate drop

below the figure specified, refer to chapter "Technical data".

Filling the sealed system

i

The water pressure at the boiler must be at least

1.2bar to operate the filling loop. If the pressure is

less than 1.2bar an external filling loop must be fitted.

If this pressure is not available contact the local water

authority.

Suitable external filling systems are shown diagrammatically, see

diagram

overleaf

.