Maintenance – Glow-worm Ultracom2 35 Store User Manual

Page 56

Advertising
background image

0020112185_PROTO_13 - 01/11 - Glow-worm

- 54 -

19.4.8

Plate-to-plate heat exchanger

• Drain the boiler heating and domestic hot water circuits as

described in the appropriate chapter "Draining".

• Remove the two securing screws (32).

• Remove the plate-to-plate heat exchanger (29).

• When replacing the plate-to-plate heat exchanger, ensure that

the four rubber sealing washers are fitted into the hydroblock.

NOTE: The plate-to-plate heat exchanger only fits one way.

• Refill, vent and pressurise the boiler.

19.4.9

Domestic hot water pump (head only)

• Drain the boiler heating and domestic hot water circuits as

described in the appropriate chapter "Draining".

• Disconnect the electrical plug (3) from the main board.

• Unscrew the nut (5).

• Carefully remove the pump head (4) together with cable.

Do not strain cable.

• Fit the new pump head by repeating the operations in reverse.

MAINTENANCE