Maintenance – Glow-worm Ultracom2 35 Store User Manual

Page 41

Advertising
background image

0020112185_PROTO_13 - 01/11 - Glow-worm

- 39 -

fault codes

Description

Cause

Solution

F32

Incorrect air pressure

Incorrect fan speed.

• Check the entire flue system.

• Check the fan’s electrical connections.

F49

EBUS voltage fault

Fault in EBUS line

Short circuit in EBUS connector

• Check that the eBus controls are fitted and wired

correctly.

F61

Fault in the main board

Gas valve command fault

• Check the main boards connections.

• Check the main board.

• Check the appliance DSN number is correct.

• Reset the appliance.

F62

Gas valve closure fault

F63

Fault in the main board memory

F64

Rapid fluctuation of return or flow

heating sensor.

F65

Excessive main board temperature

F67

Flame signal fault in the main board

F68

Fluctuation of flame signal

No return gas / Insufficient gas flow

Gas valve incorrectly adjusted

Defective firing electrode and flame

control / Defective igniter unit

• Check the return gas circuit (gas valve open).

• Check the observe the flame picture and check

the CO

2

setting.

• Check the igniter unit connections.

• Check the state of the electrode (corrosion).

F70

User interface incompatible with the

main board

Incorrect product code

• Check that the appliance DSN code on the screen

matches the product code of the nameplate (in the

event of a fault and the appliance DSN does not

appear, consult menu.d.93 reserved for the code).

• Check the boards reference.

F71

Flow heating temperature sensor fault

Flow heating temperature sensor

unclipped or defective (no temperature

variation)

• Check the sensor connections.

• Make sure that the sensor is clipped to the tube.

F72

Permanent temperature difference

between flow and return heating sensors

Mismatch between the flow and return

heating temperatures (permanent

difference)

• Check temperature sensors connections.

• Replace faulty sensors.

F73

Heating circuit pressure sensor fault

The sensor is shorted or disconnected.

• Check the sensor’s connections.

• Check the sensor.

F74

Heating circuit pressure sensor fault

Fault in pressure sensor

F76

Thermal fuse fault

Thermal fuse disconnected

Defective thermal fuse

• Check the fuses connections.

• Replace the heat exchanger.

F77

Fault in gas valve motor.

Defective gas valve.

Defective condensate pump (option)

• Check the gas valve connections.

• Check the operation of the gas valve.

• Check the operation of the condensate pump

(option).

F79

Storage tank temperature sensor fault

Storage tank temperature sensor fault

• Check the sensor connections

• Check the sensor cables

• Check the sensor

F81

Overheating of hot water circuit

Fault in the hot water circuit

• Check whether:

- temperature sensor not clipped correctly (plate

exchanger outlet)

- hot water pump not functioning

- non-return valve blocked

- plate exchanger blocked

- tank outlet pipes blocked

- air in the primary circuit

- main pump not functioning

F83

No water in the installation : the

temperature does not increase when the

burner is lit

Return water valve closed

Pump disconnected

Leak in the installation

• Fill the installation.

• Purge the installation.

• Check the pump connections.

• Check the flow and return heating sensor

connections.

• Check that there are no leaks.

F84

Permanent temperature difference

between flow and return heating sensors

Inverted or disconnected flow and

return heating temperature sensors

Defective temperature sensors

• Check temperature sensors connections.

• Replace faulty sensors.

F85

Flow and return heating sensors fault

Flow and return heating temperature

sensor connected to same tube

• Check temperature sensors connections.

F86

Underfloor heating contact fault

Floor heating contact open

Sensor disconnected or defective

• Check the sensor connections.

• Check that the sensor is connected to the main

board and the shunt is removed.

Err

User interface fault

Defective user interface

• Check connection from user interface PCB to

main PCB.

• Replace user interface.

MAINTENANCE

Advertising