background image

0020112185_PROTO_13 - 01/11 - Glow-worm

- 58 -

19.7 PCb

i

When replacing the board refer to instructions

supplied with the spare part.

19.7.1

Main PCb

230

V

E

D

D

A

B

A

C

3

4

5

6

7

2

1

Key

1 230 V access cover

2 Screw

3 Main PCb access cover

4 24 V access cover

5 Main PCb

6 Retaining clips

7 Control Panel

• Remove the 24V and 230V connections.

• Open the covers (1;3;4).

• Ease back the two PCB retaining clips (6) and withdraw the

PCB from the retaining lugs.

• Remove the electrical connections to the PCB (appliance

interface cable).

19.7.2

2A fuse Rating

• For access, refer to chapter "Main PCB".

• The fuse is located at top right hand side of the PCB, see

chapter "Electrical connection ▸ Wiring diagram".

19.7.3

User interface PCb

230

V

A

A

B

C

D

E

1

2

3

4

5

6

6

7

Key

1 Control Panel

2 User interface

3 User interface PCb

4 Retaining screw

5 bracket (Switch On/Off)

6 Retaining clips

7 User interface PCb retaining screws

• Open the user interface (2).

• Remove the retaining screws (4;7) of the bracket (5).

• Ease back the two PCB retaining clips (6) and withdraw the

PCB from the retaining lugs.

• Remove the electrical connections to the PCB.

• When refitting the user interface, ensure the leads are not

trapped.

19.7.4

Mains supply cable

e

The main supply cable must be replaced by a

qualified and competent electrician.

• If the main supply cable is damaged, replace it refering to the

chapter "Electrical connection".

MAINTENANCE