Maintenance – Glow-worm Ultracom2 35 Store User Manual
Page 49

0020112185_PROTO_13 - 01/11 - Glow-worm
- 47 -
18.8 Particle filter
1
2
Key
1
Particle filter
2 Clips
i
Remove the particle filter to check its condition.
• Check the condition of the particle filter. To remove the particle
filter (1) remove the 2 clips (2).
• The particle filter must be removed and cleaned after the first
year(s) of use.
• Clean the grill inside.
• After installing a new particle filter, refill and bleed the
appliance and the installation if necessary.
18.9 Condensate trap
a
Warning: condensate is mildly acidic. Use protective
gloves.
1
2
3
Key
1 The condensate trap
2 Discharge of
condensate
3 Siphon
• Place a container under the condensate trap (1).
• Remove the siphon (3) from
the
recoverer and clean.
• Disconnect the condensation discharge (2).
• Clean the hose, the trap and the siphon, remove any
accumulated dirt.
• Reassemble the components, taking care to position the
gaskets correctly.
• Start the siphon (3) and fill with water.
MAINTENANCE