Maintenance – Glow-worm Ultracom2 35 Store User Manual

Page 49

Advertising
background image

0020112185_PROTO_13 - 01/11 - Glow-worm

- 47 -

18.8 Particle filter

1

2

Key

1

Particle filter

2 Clips

i

Remove the particle filter to check its condition.

• Check the condition of the particle filter. To remove the particle

filter (1) remove the 2 clips (2).

• The particle filter must be removed and cleaned after the first

year(s) of use.

• Clean the grill inside.

• After installing a new particle filter, refill and bleed the

appliance and the installation if necessary.

18.9 Condensate trap

a

Warning: condensate is mildly acidic. Use protective

gloves.

1

2

3

Key

1 The condensate trap

2 Discharge of

condensate

3 Siphon

• Place a container under the condensate trap (1).

• Remove the siphon (3) from

the

recoverer and clean.

• Disconnect the condensation discharge (2).

• Clean the hose, the trap and the siphon, remove any

accumulated dirt.

• Reassemble the components, taking care to position the

gaskets correctly.

• Start the siphon (3) and fill with water.

MAINTENANCE

Advertising