Comtech EF Data CST-5000 User Manual

Page 115

Advertising
background image

Maintenance

CST-5000 C-Band Satellite Terminal

6–4

Rev. 9

Table 6-3. Fault Isolation (Continued)

Fault

Possible Problem and Action

D/C LOCK

Down converter lock fault.

Check for loose connections at P10, P11, and P4. Also, check all RF coaxial connectors
on the D/C synthesizer and D/C before replacing the modules. Once the problem has
been corrected, the transmitter must be turned back on.

Note: Not available in single synthesizer option.

IF LOCK

IF Lock fault.

Check for loose connections at P9 and P4. Also, check all RF coaxial connectors on the
IF Local Oscillator module. If all connections are good, replace the IFLO module. Once
the problem has been corrected, the transmitter must be turned back on.

IF TUN

IF Tuning fault.

Check for loose connections at P9 and P4. Also, check all RF coaxial connectors on the
IFLO module. If all connections are good, replace the IF local oscillator module. Once
the problem has been corrected, the transmitter must be turned back on.