Comtech EF Data CST-5000 User Manual

Page 27

Advertising
background image

CST-5000 C-Band Satellite Terminal

Introduction

Rev. 9

1–11

Table 1-2. RFT-500 Specifications (Continued)

Monitor and Control

Control Interface

EIA-232, EIA-485, or optional keyboard

Control Functions

SELECT

PARITY

RF OUTPUT

LNA PWR

U/C FREQ

LNA FLT

D/C FREQ

CALIB.

U/C ATTN

REF ADJ

D/C ATTN

XFLT EN

PROGRAM RSW

MODE

BAUD LOCK

MODE

ADDRESS

Monitor Functions

U/C TEMP

TUV

D/C TEMP

TDV

HPA TEMP

TIV

Fault Detect Functions

RESTART

U/C LOCK

UPLINK U/C

TUN

DOWNLINK D/C

LOCK

5V PWR

D/C TUN

12V PWR

IF LOCK

HPA IF

TUN

LNA


Table 1-3. LNA Specifications

LNA Dimensions

Refer to Figure 1-5 or 1-6, respectively

Frequency

3.620 to 4.200 GHz

Noise Temperature (with TRF)

65

°

K maximum (lower temperatures optional)

Gain

50 dB minimum, 54 dB nominal
(optional 60 db)

Gain Flatness

±

1 dB/575 MHz

Gain vs. Temperature

±

3 dB maximum

1 dB Compression Point

+10 dBm minimum

Third Order Intercept

+20 dBm minimum

Group Delay:

Linear
Parabolic
Ripple

±

0.01 ns/MHz maximum

0.001 ns/MHz

2

maximum

0.1 ns P-P

Input VSWR

1.25:1

Output VSWR

1.25:1

Input Connector

CPR229G (hold pressure to 0.5 PSIG)

Output Connector

Type N

Spurious

Below thermal noise/100 kHz

TRF Rejection

60 dB

Advertising