A.2.1 Remote Control Operation

This section describes the remote control operation differences between the standard
firmware for the RFT-500 (FW/3059-2N) and the firmware supported for the CST-5000
Multi-Carrier System (FW/3059-3-).

Note: The firmware referenced in this manual may be an earlier version of the actual
firmware supplied with the unit.

The following additional commands are supported:

External
Fault Uplink

Command:
Response:

Status:
Response:

<add/XFU_xxx'cr'
>add/XFU_xxx'cr''lf']

<add/XFU_'cr'
>add/XFU_xxx'cr''lf']

Where: xxx = ON or OFF (default = OFF, disable monitor).

Monitors external uplink fault.

External
Fault
Downlink

Command:
Response:

Status:
Response:

<add/XFD_xxx'cr'
>add/XFD_xxx'cr''lf']

<add/XFD_'cr'
>add/XFD_xxx'cr''lf']

Where: xxx = ON or OFF (default = OFF, disable monitor).

Monitors external downlink fault.


The following command is not supported:

External
Fault
Enable

Command:
Response:

Status:
Response:

<add/XFE_xxx'cr'
>add/XFE_xxx'cr''lf']

<add/XFE_'cr'
>add/XFE_xxx'cr''lf']

Where: xxx = ON (the default) or OFF.

This command is used to replace the internal HPA fault signal
with a customer-supplied fault signal from an external HPA as
the source of the HPA fault in the 'FS_' command.

The external source interfaces with the RF terminal at
connector J6, pin M. This signal must be an OPEN/GND
signal, with OPEN defined as the fault condition.