Comtech EF Data CST-5000 User Manual

Page 68

Advertising
background image

Redundant System Installation

CST-5000 C-Band Satellite Terminal

3–14

Rev. 9

a. Lift the RFT into position on

the vertical pole.


b. Slip a 14 inch (35.6 cm)

unistrut over each of pair of
threaded rods (upper and
lower).

Note: Install the 14 inch
(35.6 cm) unistruts with the
open face toward the pole, as
illustrated.


c. Install a 5/16 inch (8 mm) flat

washer, 5/16 inch (8 mm)
split lockwasher, and 5/16-18
nut on each threaded rod.


d. Position the RFT, as desired,

and tighten the 5/16-18 nuts
installed in Step 6.c.


e. Slide the pipe blocks in until

they contact the vertical pole.


Then, firmly tighten the
5/16-18 bolts.



3.3.2.2 Square Pole

For square, vertical pole installation, follow the steps in Section 3.3.2.1, with the
following exceptions:

• Do not perform Step 4.
• Do not perform Step 6.e.