Comtech EF Data CST-5000 User Manual
Page 68
Redundant System Installation
CST-5000 C-Band Satellite Terminal
3–14
Rev. 9
a. Lift the RFT into position on
the vertical pole.
b. Slip a 14 inch (35.6 cm)
unistrut over each of pair of
threaded rods (upper and
lower).
Note: Install the 14 inch
(35.6 cm) unistruts with the
open face toward the pole, as
illustrated.
c. Install a 5/16 inch (8 mm) flat
washer, 5/16 inch (8 mm)
split lockwasher, and 5/16-18
nut on each threaded rod.
d. Position the RFT, as desired,
and tighten the 5/16-18 nuts
installed in Step 6.c.
e. Slide the pipe blocks in until
they contact the vertical pole.
Then, firmly tighten the
5/16-18 bolts.
3.3.2.2 Square Pole
For square, vertical pole installation, follow the steps in Section 3.3.2.1, with the
following exceptions:
• Do not perform Step 4.
• Do not perform Step 6.e.