Comtech EF Data CST-5000 User Manual

Page 139

Advertising
background image

Remote Control Operation

CST-5000 C-Band Satellite Terminal

B–6

Rev. 9

Select
Preset
Config

Command:
Response:

Status:
Response:

<add/SEL_n'cr'
>add/SEL_n'cr''lf']

<add/SEL_'cr'
>add/SEL_'cr''lf']

Where: n = 1, 2, or 3.

1

UCF_nnnn.n'cr'

nnnn.n = 5845.0 to 6425.0 MHz.

DCF_nnnn.n'cr'

nnnn.n = 3620.0 to 4200.0 MHz.

UCA_nn.n'cr'

nn.n = 0.0 to 25.0 dB (UC Fine Adj).

DCA_nn.n'cr''lf']

nn.n = 0.0 to 21.0 dB (DC Fine Adj).


2

UCF_nnnn.n'cr'

nnnn.n = 5845.0 to 6425.0 MHz.

DCF_nnnn.n'cr'

nnnn.n = 3620.0 to 4200.0 MHz.

UCA_nn'cr'

nn.n = 0.0 to 25.0 dB (UC Fine Adj).

DCA_nn'cr''lf']

nn.n = 0.0 to 21.0 dB (DC Fine Adj).


3

UCF_nnnn.n'cr'

nnnn.n = 5845.0 to 6425.0 MHz.

DCF_nnnn.n'cr'

nnnn.n = 3620.0 to 4200.0 MHz.

UCA_nn'cr'

nn.n = 0.0 to 25.0 dB (UC Fine Adj).

DCA_nn'cr''lf']

nn.n = 0.0 to 21.0 dB (DC Fine Adj).


Allows the user to select any one of three 'Preset'
configurations. The users must first program (store) a
configuration using the 'PGM_n' command defined below. This
command used without the 'Preset' number (n) will provide the
current programming of each of the three 'Presets.'

Program
Preset
Config

Command:
Response:

Status:
Response:

<add/PGM_n'cr'
>add/PGM_n'cr''lf']

<add/PGM_'cr'
>add/PGM_'cr''lf']

Where: n = 1, 2, or 3.

1

xxxxxxxxxx'cr''lf']

xxxxxxxxxx = 'Programmed' or 'None'.


2

xxxxxxxxxx'cr''lf'].


3

xxxxxxxxxx'cr''lf'].


Allows the user to store (program) the current frequency and
attenuator settings as one of three 'Preset' selections.

Clear
Program
Preset
Config

Command:
Response:

Status:
Response:

<add/CPGM_n'cr'
>add/CPGM_n'cr''lf']

<add/CPGM_'cr'
>add/CPGM_'cr''lf']

Where: n = 1, 2, or 3.

1

xxxxxxxxxx'cr''lf']

xxxxxxxxxx = 'Programmed' or 'None'.


2

xxxxxxxxxx'cr''lf'].


3

xxxxxxxxxx'cr''lf'].


Allows the user to clear (unprogram) the frequency and
attenuator setting for one of three 'Preset' selections.

Lock Mode

Command:
Response:

Status:
Response:

<add/LM_xx'cr'
>add/LM_xx'cr''lf']

<add/LM_'cr'
>add/LM_xx'cr''lf']

Where: xx = LK (lock) or EN (default, enable).

Lock mode prevents the current settings from being changed.

RS-232-C
Address
Select

Command:
Response:

Status:
Response:

<add/AS_xxx'cr'
>add/AS_xxx'cr''lf']

<add/AS_'cr'
>add/AS_xxx'cr''lf']

Where:

add = current address.
xxx = new address, 1 to 255.

Default address = 1.